Справочник Пользователя для Empire Comfort Systems 21)L(N

Скачать
Страница из 28
Page 18
20101-0-0306
WARNING:  If you do not follow these instructions exactly, a fire or explosion may result 
causing property damage, personal injury or loss of life.
A.   This  appliance  has  a  pilot  which  must  be  lighted  by 
hand.  When lighting the pilot, follow these instructions 
exactly.
B.   BEFORE LIGHTING  smell all around the appliance 
area for gas.  Be sure to smell next to the floor because 
some gas is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; 
  Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's 
phone.  Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire 
department.
C.   Use only your hand to push in or turn the gas control 
knob.  Never use tools.  If the knob will not push in or 
turn by hand, don't try to repair it; call  a  qualified 
service technician.  Force or attempted repair may 
result in a fire or explosion.
D.   Do not use this appliance if any part has been under 
water.  Immediately call a qualified service technician 
to inspect the appliance and to replace any part of 
the control system and any gas control which has 
been under water.
3.   Push in gas control knob slightly and turn clockwise  
  to "OFF".  Do not force.
TO TURN OFF GAS TO APPLIANCE
1.   Set thermostat (gas control knob) to lowest setting.
2.   Turn off all electric power to appliance if service is to be 
performed (if applicable).
LIGHTING INSTRUCTIONS
in for about one (1) minute after the pilot is lit. Release 
knob and it will pop back up. Pilot should remain lit. If 
it goes out, repeat steps 4 through 8.
 •  If knob does not pop up when released, stop and 
immediately  call  your  service  technician  or  gas 
supplier. 
 •  If the pilot will not stay lit after several tries, turn 
the gas control knob to "OFF" and call your service 
technician or gas supplier. 
 9.  Attention!  Gas  control  has  an  INTERLOCK  latching 
device. When the pilot is initially lit and the safety magnet 
is energized (pilot stays "ON") the INTERLOCK latching 
device becomes operative. If the gas control is turned to 
the "OFF" position or gas flow to the appliance is shut 
off, the pilot cannot be relighted until the safety magnet 
is de-energized (approximately 60 seconds). There will 
be an audible "click" when the safety magnet in the gas 
control is de-energized. Pilot can now be relighted. Repeat 
steps 4 through 8.
10.  Turn  gas  control  knob  counterclockwise 
  to 
"5". 
11.  Turn on all electric power to appliance (if applicable).
12.  Set thermostat (gas control knob) to desired setting from 
"5" to "1 ".
1.   STOP!  Read the safety information above.
2.  Set thermostat (gas control knob) to lowest setting.
3.  Turn  off  all  electric  power  to  the  appliance  (if  appli-
cable).
4.   Push in gas control knob slightly and turn clockwise            
 
 to "OFF". Do not force.
 
5.   Wait ten (10) minutes  to clear out any gas. Then smell 
for gas, including near the floor. If you smell gas, STOP! 
Follow "B" in the safety information above. If you don't 
smell gas, go to the next step.
6.   Find pilot - the pilot is 
 
in front of the rear log
7.   Turn gas control knob
 
counterclockwise
 to 
 
"PILOT."
8.   Push in gas control knob all the way and hold in. Repeat-
edly push the piezo ignitor button until pilot is lit (or use 
a match to light pilot). Continue to hold the control knob 
VFP(32,36)FP(20,21) LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING