Flames from the pilot (rear right back side of the pan burner) as 
well as the main flame should be visually checked as the log set 
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame 
appearance should be sets of yellow flames.
NOTE: All flames will be random by design, flame height will 
go up and down.
Glowing embers (rock wool) can cover the pan burner in between 
the front and middle logs, but very little is necessary to cover this 
area. Excess ember material causes the yellow flame to become 
orange and stringy. Apply just enough to obtain slow glow and a 
gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow 
fans to blow directly into fireplace. Do not place a blower inside 
the burner area of the firebox. Ceiling fans may create drafts that 
alter flame patterns. Sooting and improper burning will result.
During  manufacturing,  fabricating  and  shipping,  various 
components of this appliance are treated with certain oils, films or 
bonding agents. These chemicals are not harmful, but may produce 
annoying smoke and smells as they are burned off during the initial 
operation of the appliance, possibly causing headaches or eye or 
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner 
at the highest setting. Provide maximum ventilation by opening 
windows or doors to allow odors to dissipate. Any odors remaining 
after this initial break-in will be slight and will disappear with 
continued use.
PERIODIC CLEANING – Refer to parts diagram for location 
of items discussed below.
•  Do  not  use  cleaning  fluid  to  clean  logs  or  any  part  of 
heater.
•  Logs - brush with soft bristle brush or vacuum with brush 
attachment.
•  Remove  loose  particles  and  dust  from  the  burner  areas, 
controls, piezo covers and grate. Don’t remove ceramic media 
from inside burner box.
•  Inspect  and  clean  burner  air  intake  hole.  Remove  lint  or 
particles with brush. Failure to keep air intake hole clean will 
result in sooting and poor combustion.
ANNUAL  CLEANING/INSPECTION  –  Refer  to  parts 
diagram for location of items discussed below.
•  Inspect  and  clean  burner  air  intake  hole.  Remove  lint  or 
particles with vacuum or brush. Failure to keep air intake 
hole clean will result in sooting and poor combustion.
•  Inspect and clean all burner ports.
•  Inspect ODS pilot for operation and accumulation of lint at 
air intake holes.
•  Verify  flame  pattern  and  log  placement  for  proper 
operation.
•  Verify smooth and responsive ignition of main burner.
•  Check level of ceramic media in burner. Burner should be 
full, up to the level of openings in burner top.
OPERATION INSTRUCTIONS/FLAME APPEARANCE