Справочник Пользователя для Paradyne CSU

Скачать
Страница из 470
F. Technical Specifications
F-6
  
September 
2002
9128-A2-GB20-80
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
35
°
F to 122
°
F ( 1.7
°
C to 50
°
C)
– 4
°
F to 158
°
F ( –20
°
C to 70
°
C)
5% to 85% ( noncondensing )
Withstands normal shipping and handling
Physical Dimensions
Height
Width
Depth
10.5 inches
 
(26.7 cm) or 6U
17.2 inches (43.7 cm)
14.3 inches
 
(36.3 cm)
Weight
Empty access carrier (without power supply)
11 lbs. 6 oz. (5.16 kg)
AC Power Requirements
AC Power Supply
DC Power Supply
90 to 265 VAC,  50/60 Hz 
±
3A maximum
– 48 VDC, 6.6 amps, 316 watts
Heat Dissipation (Max.)
227 VAC
– 48 VDC
Fully loaded access carrier
585 Btu per hour maximum
465 Btu per hour maximum
Typical Power Consumption
AC Power Supply
1 power supply installed
2 power supplies installed
DC Power Supply
1 power supply installed
2 power supplies installed
100 VAC    60 Hz    1.7 amps    171 watts
120 VAC    60 Hz    1.03 amps    60 watts
100 VAC    50 Hz    1.15 amps    60 watts
Result: 207 Btu per hour
100 VAC    60 Hz    1.25 amps    64.5 watts
120 VAC    60 Hz    1.5 amps    177 watts
230 VAC    50 Hz    0.9 amps    172 watts
Result: 221 Btu per hour
104 watts at – 48 VDC
Result: 355 Btu per hour
124 watts at – 48 VDC
Result: 423 Btu per hour
Table F-3.
14-Slot 9000 Series Access Carrier Technical Specifications (2 of 2)
Specification
Criteria