E. Food Storage
• This unit is designed only for temporary storage of food. Employ sanitary methods. Use 
for any other purposes (for example, storage of chemicals or medical supplies such as 
vaccine and serum) could cause deterioration of stored items.
• Do not block the air inlet and outlet or cooling performance may be reduced.
• Do not pack the cabinet tightly with food. Allow some space between items/containers to 
ensure good air flow. Also allow space between food product and interior surfaces. 
• Do not put warm or hot foods in the unit. Let them cool first, or they will raise the cabinet 
temperature and could deteriorate other foods in the cabinet or overload the unit.
• All foods should be wrapped in plastic film or packed in a container. Otherwise foods 
may dry up, pass their smells onto other foods, cause frost to develop, result in poor unit 
performance, or increase the likelihood of cross-contamination. Certain dressings and     
food ingredients, if not stored in containers, may accelerate corrosion of the evaporator, 
resulting in failure.
• On Roll In or Roll Thru units, before rolling the food cart into the cabinet, ensure that all 
food containers are arranged evenly and not protruding beyond the cart.
• On Roll In or Roll Thru units, place the food trays evenly from the bottom first on the food 
cart to reduce the risk of tipping the food cart.
F. Perimeter Frame Heater
This unit is equipped with a perimeter frame heater. This prevents the formation of 
condensate on the front frame and rear frame (Pass Thru and Roll Thru) of the unit 
under high humidity conditions. If operating the unit under conditions where condensate 
will not form, these heaters may be turned off using the switch on the control box.
G. Safety Devices
1. High Pressure Switch
• If pressure on the high-side of the unit exceeds Hoshizaki specifications, a high 
pressure switch activates and interrupts power to the compressor relay. This power 
interruption shuts down the compressor.
• The high pressure switch resets automatically.
2. Compressor Short Cycle Timer
a) TempGuard Models
There is a  1/ minute minimum off-time and on-time for the compressor.
• Any time the compressor is started, it will keep running for a minimum of  1/ minutes.
• Any time the compressor is turned off, it will stay off for a minimum of  1/ minutes.
Note: Time may vary with high pressure switch activation.
b) SafeTemp Models
There is a  minute minimum off-time and on-time for the compressor.
• Any time the compressor is started, it will keep running for a minimum of  minutes.
• Any time the compressor is turned off, it will stay off for a minimum of  minutes.
Note: Time may vary with pressure switch activation.