Precision Miter Gauge
Setting the miter gauge angle
Referring to Figure 17:
The precision miter gauge has a rack and pinion
adjustment for setting the angle. To operate:
adjustment for setting the angle. To operate:
1. Slide the miter gauge into one of the slots on
the table top.
2. Loosen
lock handle (A).
To adjust the body (B) of the miter gauge to the
desired angle:
desired angle:
3. Pull
the
spring-loaded knob (C) out and turn
until the body (B) of the miter gauge is at the
desired angle as indicated on the scale.
desired angle as indicated on the scale.
4. Tighten
the
lock handle (A).
Indent settings
There are indents at the 0º, 30º and 45º right and
left positions. At these settings, release the
knob (C) to engage the stop rod. Then tighten the
lock handle (A).
left positions. At these settings, release the
knob (C) to engage the stop rod. Then tighten the
lock handle (A).
Note: Do not rely solely on the indents for an
accurate setting. After the stop rod engages at the
0º, 30º and 45º positions, make a fine adjustment
with the knob (C) by pulling out and rotating, if
necessary, setting it against the scale indicator.
accurate setting. After the stop rod engages at the
0º, 30º and 45º positions, make a fine adjustment
with the knob (C) by pulling out and rotating, if
necessary, setting it against the scale indicator.
Extension plate
The extension plate (D) can be adjusted by sliding
to the right or left or removed entirely.
to the right or left or removed entirely.
To adjust – loosen two lock handles (E), position
the extension plate and tighten the lock handles.
the extension plate and tighten the lock handles.
To remove – slide the extension plate completely
off and remove the lock handles (E) and mounting
hardware.
off and remove the lock handles (E) and mounting
hardware.
Calibrating the miter gauge
1. Place the miter gauge in one of the slots (H)
on the table top.
2. Set the miter gauge to 90º (0º setting on the
scale) by loosening the lock handle (A), then
pulling the spring-loaded knob (C) out and
turning the body (B) until 0º is indicated on
the scale (F).
pulling the spring-loaded knob (C) out and
turning the body (B) until 0º is indicated on
the scale (F).
3. Measure the accuracy of the gauge against
the slot with a combination square.
If adjustment is necessary:
4. Adjust
the
body (B) until it is perfectly square
(90º) to the miter slot (H).
Figure 17
5. Tighten
the
lock handle (A).
Verify that the scale indicator (G) reads 0º. If
further adjustment is necessary:
further adjustment is necessary:
6. Loosen the screw (F) and adjust the
indicator (G) until it reads 0º
7. Tighten
the
screw (F).