Maintenance 
Never perform maintenance on 
this machine before turning switch off and 
removing plug from power source. Failure to 
comply may cause serious injury!
 
Cleaning the Filter Bag – DC-1100A/RC 
 
Wearing a particle mask or 
respirator for protection against fine dust 
particles during cleaning is highly recommended. 
During first use and after cleaning, the filter bag may 
allow some dust to escape.  This is normal and will 
stop after a short period of time. 
Clean both the filter and collector bags frequently to 
keep the collector's performance at its optimum.  To 
clean: 
1.  Disconnect the machine from the power source. 
2.  Unhook the filter bag from the hanger and shake 
the bag so that the majority of the dust falls into 
the collector bag. 
3.  Loosen the retaining strap, and remove the filter 
bag from the housing. 
4.  Turn the bag inside out and clean. 
5.  Turn the bag outside in and re-attach to the 
housing using the retainer strap to secure. 
Removing the Collector Bag – 
DC-1100A/RC 
1.  Disconnect the machine from the power source. 
2.  Remove the collector bag by pushing the ring of 
the collector bag upwards and pulling the bag 
out at an angle.   
3.  Empty the contents into an appropriate 
container. 
4.  Turn the bag inside out and clean. 
5.  Turn the bag outside in and insert into the 
housing. 
To replace the collector bag, refer to the Collector 
Bag Installation – DC1100A/RC
 section. 
Use the proper type hose to connect the dust 
collector to the machine being operated.  Dryer vent 
hose is not acceptable for this purpose.  Contact your 
nearest JET distributor for the full line of JET Dust 
Collector Hoses and Accessories
.  Customize your 
installation and obtain maximum performance with 
JET's dust hoods, hoses, clamps, fittings, and blast 
gates. 
Cleaning the Filter – DC-1100C/RC 
Never perform maintenance on 
this machine before turning switch off and 
removing plug from power source. Failure to 
comply may cause serious injury!
 
Clean both the filter and collector bags frequently to 
keep the collector's performance at its optimum. 
To clean the filter, turn the handle a couple of 
rotations so the dust falls into the collector bag. 
Removing the Collector Bag – 
DC-1100C/RC 
Wearing a particle mask or 
respirator for protection against fine dust 
particles during cleaning is highly recommended. 
1.  Disconnect the machine from the power source 
outlet. 
2.  Remove the collector bag by pushing the ring of 
the collector bag upwards at an angle and 
pulling the bag and snap ring out. 
3.  Empty the contents into an appropriate 
container. 
To replace the collector bag, refer to the Collector 
Bag Installation – DC-1100C/RC
 section. 
Motor 
Make frequent inspections of the motor fan and blow 
out (with low pressure air hose) or vacuum any 
accumulation of foreign material in order to maintain 
normal motor ventilation.   
Connecting the Dust Collector to a 
Machine 
Use the proper type hose to connect the dust 
collector to the machine being operated.  Dryer vent 
hose is not acceptable for this purpose.  Contact your 
nearest JET distributor for the full line of JET Dust 
Collector Hoses and Accessories.  Customize your 
installation and obtain maximum performance with 
JET's dust hoods, hoses, clamps, fittings, and blast 
gates. 
Grounding the Dust Collection System 
The dust collection system includes the dust collector 
and the hose, or ductwork you use to connect the 
tools.  The dust collector is grounded though the 
ground wire in the cord.  The hose or ductwork you 
use to connect the tool to the dust collector must also 
be grounded.  To assist in grounding your system 
you can purchase the JET “Dust Collector Grounding 
Kit” stock # JW1053 through JET Distributors.