Form P7707, Edition 1
LUBRICATION
Always use an air line lubricator with these tools. We 
recommend the following Filter-Lubricator-Regulator Unit:
For International- No. FRL30-C6-A29
For USA- No. C31-06-G00
After each forty-eight hours of operation, or as experience 
indicates, inject about 4 cc of Ingersoll-Rand No. 170 Grease 
into the Grease Fitting (18).
INSTALLATION
(Dwg. TPD905-2)
SPECIFICATIONS
„
Tested in accordance with ISO15744 at free speed.

Tested to EN/ISO8662–7 loaded with frictionbrake to 9 RPM
Measurement uncertainty of the Sound Pressure Level ‘Kpa’ = 3dB(A)
z
Measurement uncertainty of the Sound Power Level ‘Kwa’ = 3dB(A)
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
When the life of the tool has expired, it is recommended that the tool be disassembled, degreased and parts be 
separated by material so that they can be recycled.
Ingersoll-Rand No. 50
Ingersoll-Rand No. 170
Model
Handle
Drive
Impacts
/ min.
Recommended
Torque Range
 Sound Level
dB (A)
 Vibrations
Level
Inlet
Connection
(Thread)
Minimum
Inside Ø
(Air Hose)
I.D.
Type
in.
bpm
ft-lbs (Nm)
Pressure
(  Lp)
Power
 Lp)
m/s
2
NPT
in. (mm)
2190Ti
grip
1” sq. dr.,
inside trigger
875
150-1200
(204-1627)
103.8
116.8
8.3
1/2
1/2 (13)
2190Ti-6
grip
1” x 6” extended 
sq. dr, inside 
trigger
875
150-1200
(204-1627)
103.8
116.8
9.8
1/2
1/2 (13)
2190DTi-6
D
1” x 6” extended 
sq. dr, inside 
trigger
875
150-1200
(204-1627)
103.8
116.8
9.8
1/2
1/2 (13)
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut-Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly