WOOD/COMPOSITE OVERLAY INSTALLATION
(Including Custom Ventilator Installation)
The bottom of a standard hood should be 30” (76.2 cm) min to 36” (91.4 cm) max above the ceramic glass
surface.  This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor.
Refer to the rangehood installation instructions for further information.  These dimensions provide for safe and
efficient operation of the hood.
30” (76.2 cm) min
36” (91.4 cm) max
66” - 72”
(167.6 cm - 
182.9 cm)
30” (76.2 cm) min
36” (91.4 cm) max
66” - 72”
(167.6 cm - 
182.9 cm)
36”
(91.4 cm)
ISLAND INSTALLATION
WALL INSTALLATION
36”
(91.4 cm)
Metal Hood
Metal Hood
W ood/Composite Overlay
W ood/Composite Overlay
Countertop
Countertop
ELECTRICAL CONNECTION
With the rangetop positioned in front of the cabinet opening, connect the
wire leads extending from the conduit to the junction box, making sure the
neutral (white) wire is connected to the appropriate terminal.  Check your
local codes to see which of the options below should be used in grounding
the unit.  Do not use GFI circuit.
OPTION 1
Connnect the neutral (white) wire and the grounding
(bare) wire with the incoming neutral (white) power
supply lines.
OPTION 2
If the junction box is grounded, untwist the grounding
(bare) wire and attach to the junction box.  Attach the
neutral (white) wire to neutral (white) power supply line.
Identification Label Location -
(bottom of unit in left rear corner)