44 
System Menu Option 
LDS Plus Reference Guide 
E-SW-LDSPLUSRG-G 
DockedIO – Docked I/O Configuration 
Function 
The DockedIO parameter specifies which comm port to use as local input (for a barcode scanner) 
and which one to use as local output (for a printer). This parameter only affects operation of the 
MX1 and MX3 when they are docked.  This parameter is valid for MX1 and MX3 only. 
The MX1 supports endcaps with an integrated scanner, an RS-232 port or both. A selection of a 
DockedIO configuration that is not fully supported by the endcap will result in partial 
functionality. The TE will not attempt to correct the selection. 
The MX3 COM2 port supports both an IR port and an RS-232 port. The power is applied to the 
port configured as input until the computer receives a print command. At that time, the power is 
switched to the port configured as output. When the print command is completed, power is 
returned to the input port. This configuration option allows dual scanning through a cradle. 
Options 
MX1  
Valid options: 
Not supported 
COM1 RS-232 
Not supported 
 
 
 
COM1 Scanner    
Not supported 
 
 
 
COM2 IR 
Not supported 
 RS-IN/OUT:IR:IN 
COM1 
RS-232 
Input/Output 
 
 
 
COM1 Scanner    
N/A 
  
 COM2 
IR 
Input 
 IS-IN:IR-IN/OUT 
COM1 
RS-232 
N/A 
 
 
 
COM1 Scanner    
Input 
 
 
 
COM2 IR  
Input/Output 
 RS-IN:IR-IN/OUT 
COM1 
RS-232 
Input 
 
 
 
COM1 Scanner  
N/A 
  
 COM2 
IR 
Input/Output 
 IS&RS-IN:RS-OUT 
COM1 
RS-232 
Output 
 
 
 
COM1 Scanner  
Input 
 
 
 
COM2 IR  
Input 
Default setting:  Not supported 
                                                           
2
  Defaults to undocked configuration.  See Normal IO.