Symbol Barcodes 
Integrated Scanner Programming Guide 
 
E-SW-SCANNERPG-L 
Trigger Mode 
Scanner: 
 
2223  1524 1224 1223  955  923  824 
Note:  LXE mobile devices with integrated scanners are designed to be operated in Level Trigger 
Mode. LXE recommends leaving the Trigger Mode default value unchanged. 
Parameter Default Value: 
Level 
Use this parameter to determine when the integrated laser is activated and decoding begins, how long 
the laser remains on and what determines the cessation of the laser scan and decode process. 
Select a trigger mode by scanning the appropriate barcode. If you wish to change your selection, scan 
Cancel. 
Level 
A trigger pull or SCAN key press activates the laser and decode 
processing. The laser remains on and decode processing continues 
until a trigger release, a valid decode or the Laser On Time-out is 
reached. 
Level
 
Pulse 
A trigger pull or SCAN key press activates the laser and decode 
processing. The laser remains on and decode processing continues 
until a valid decode, or the Laser On Time-out is reached. 
Pulse
 
Continuous 
The laser is always on and decoding. 
Continuous
 
See Also 
Time-out Between Same Symbol 
Blinking 
This trigger mode is used for triggerless scanning operations. 
Scanning range is reduced in this mode. This mode cannot be used 
with scanners that support an aim mode (e.g. the SE1223/SE1224LR 
Long Range scanner endcap). 
Blinking