Appendix A    RAC Parameters
Managing Remote Access Concentrators Using Annex Manager
CallDef_forwarding_
timer
sets the amount of time in ten millisecond intervals that can elapse before a RAC
or an ISDN Primary Rate RAC forwards received data. If new data arrives before
the timer expires, the RAC resets the timer. If you enter
0
, the RAC uses
5
, which
is the Annex Manager default value.
Setting
CallDef_forwarding_count
 to
1
 or
CallDef_forwarding_timer
 to
0
 can
have a severe effect on the network when heavy serial input occurs.
CallDef_hardware_tabs
allows a RAC or an ISDN Primary Rate RAC to convert ASCII tab characters
to the correct number of spaces when a terminal does not support hardware tabs.
This parameter works only for CLI sessions.
CallDef_Imask_7bits
allows a RAC or an ISDN Primary Rate RAC to mask input to seven bits. If you
choose
disabled
, the RAC expects eight-bit ASCII input.
Type
RAC
Values
0 to 255 tens of milliseconds
Default
5 (50 milliseconds)
Lists
RAC Only, Call Defaults, Idle Timer
Type
RAC
Values
enabled or disabled
Default
enabled
Lists
RAC Only, Call Defaults, Cmd Line Editing
Type
RAC
Values
enabled or disabled
Default
disabled
Lists
RAC Only, Basic Async Port, Call Defaults