Справочное Руководство для Intermec 9710

Скачать
Страница из 109
C d 39
 Microterm 5530 
65 
 
 Microterm 5530 
This section covers the Microterm 5530 workstation. The individual Wedge Interface 
Guide corresponding to this section is part number 054834. 
Cables 
Connecting the reader to the workstation requires two cables: a keyboard cable and a 
terminal cable. The interface kit contains both the keyboard and terminal cables. If you 
need to order a replacement cable, use the part numbers listed below: 
•  Wedge interface kit (P/N 054833) 
•  Keyboard cable (P/N 054832) 
•  Terminal cable (P/N 054831) 
Power Supply 
The reader requires an external power supply to work with the workstation. Set the PCB 
jumper to connect pins 2 and 3 on the reader’s rear panel. 
 
Note: If you are using an external power supply with the reader, plug in the power 
supply before powering ON the workstation. If you do not, the reader will lock up. 
Configuring the Reader 
Scan this label to configure the reader for your workstation. After the label is scanned, 
the reader emits one low beep followed by four low beeps. The four low beeps indicate 
the reader has successfully stored the configuration and is ready to read labels. If the 
reader emits a different beep sequence, refer to the Wedge Reader User’s Manual
Section 2, for beeper identification. 
Microterm 5530 
*$+TA136* 