EXTender 1100A        Remote Module: Quick Installation Guide 
13
 
Setting up the COM Port 
The Remote Module can be configured through the serial port when using a 
terminal emulator such as Windows HyperTerminal. The following are the steps 
necessary to access the Remote Module’s Management Console. 
1.  Start a HyperTerminal session. On a default installation of Windows XP, for 
example, at the Start menu select ProgramsAccessories
Communications and finally HyperTerminal
2.  Enter a name for the new connection in the Name box – Remote, for 
example 
3.  Select the COM port you are using from the options in the Connect drop-
down list 
4.  Check the configuration of the communications port and make sure that the 
settings are as follows: 
Bits per second 
9600 
Data bits 
Parity None 
Stop bits 
Flow Control 
None 
5.  Plug the power supply in to the Remote Module and then into the AC wall 
outlet. Allow the unit to complete the bootup sequence. 
6.  Wait a few seconds and the “Press ‘Enter’ to start the shell…” prompt is 
displayed. 
7.  Press Enter. A password prompt is displayed if a password is set (there is no 
default password). 
If the Remote Module is running but you do not see these prompts the serial 
connection between your computer and the unit may be at fault. You must 
correct this problem before you can use the HyperTerminal connection 
successfully. 
8.  Type the unit’s password, if one was set, and press Enter. The Management 
Console welcome screen is displayed 
9.  To ensure that you can see all the information displayed you must set the 
screen size to 24 lines by 80 columns. The screen size is correctly set when 
the Welcome screen is displayed with the ‘#’ border. 
 