EXTender 1100A        Remote Module: Quick Installation Guide 
15
 
4 C
ONFIGURING THE 
R
EMOTE 
M
ODULE
 
This chapter describes the necessary steps to configure the Remote Module 
using the Management Console (MC). The unit is programmed at the factory with 
default settings to provide the basic parameters to accommodate most network 
environments. 
The Setup Wizard 
After the unit has been powered up a series of self diagnostics tests will be 
performed. When complete, the following prompt will be presented: 
Press ‘Enter’ to start the shell... 
If power is supplied to the Remote Module prior to running Windows 
HyperTerminal (or equivalent communications software) this message will not be 
displayed. 
Pressing Enter will result in the administrator being prompted to run the Setup 
Wizard. The Setup Wizard will ask the administrator a series of questions to 
assist with the configuration process. It is highly recommended that the Setup 
Wizard be run at the start of any new installation. The administrator can also run 
the Setup Wizard at any time to change the configuration parameters: 
Path: Remote->Utilities->Setup Wizard 
 
Follow the Setup Wizard to configure the Minimum Required parameters: 
1.  A unique name for the Remote (i.e. Mike’s Home Office) 
2.  Region Code – the region is set automatically depending on the country code 
selected 
3.  Select the appropriate PBX type 
4.  Enable or disable the Leased Line Mode depending on the analog line type 
being used 
5.  Enter the Office Dial Number – this is the phone number of the analog line 
that is connected to the Switch Module (only required if Leased Line is 
disabled). 
Additional Configuration Parameters: 
6.  Manually enter the Connect Rate (default is Auto) 
7.  Enable or disable Pulse Dialing depending on the analog line service 
8.  Enable or disable Dialback – the Dialback feature is used for the Switch to 
automatically call back the remote during a connection attempt 
9.  Enter a User ID (if required) – the User ID is used to “map” the port to a 
specific port on the Switch Module. Typically used for connecting to one of 
 