To do… 
Use the command… 
Remarks 
Configure the Hello timer and 
Fail timer for the RRPP domain 
timer hello-timer hello-value 
fail-timer
 fail-value 
Required 
By default, the Hello timer value 
is 1 second and the Fail timer 
value is 3 seconds. 
 
 
The Fail timer value must be equal to or greater than three times the Hello timer value.  
To avoid temporary loops when the primary ring fails in a dual-homed-ring network, ensure that the 
difference between the Fail timer value on the master node of the subring and that on the master 
node of the primary ring is greater than twice the Hello timer value of the master node of the 
subring.  
 
Configuring RRPP Fast Detection 
 
The S7900E series Ethernet switches support RRPP fast detection only after SD or EB cards are 
mounted in them. 
 
Enabling Fast Detection 
Perform this configuration on the master node, edge node, and assistant-edge node in the RRPP 
domain to be configured.  
Follow these steps to enable fast detection: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter RRPP domain view 
rrpp domain domain-id 
— 
Enable fast detection 
fast-detection enable 
Required 
Disabled by default 
 
 
To configure fast detection on the master node of a subring, make sure that the edge node and 
assistant-edge node of the subring supports fast detection. Otherwise, you are not recommended to 
configure fast detection on the master node of the subring.