Краткое Руководство По Установке для 3com S7906E

Скачать
Страница из 155
 
1-6 
Figure 1-6 Front panel of the S7906E 
(1)
(3)
(4)
(5)
(2)
(3)
 
(1) Fan tray 
(2) Jack for ESD-preventive wrist strap 
(3) Power module 
(4) LPUs (in slot 2 to slot 7) 
(5) SRPUs (in slot 0 and slot 1) 
 
All the modules of the S7906E are hot swappable.  
The S7906E has eight horizontal slots. SRPUs are inserted in the upper two slots (see callout (5) in 
). SRPUs are required and support active-standby switchover. Different LPUs are 
inserted into the other six slots (see callout (4) in 
). 
The fan tray is installed on the right side of the chassis (see callout (1) 
The two power modules, which sit in the lower part of the chassis (see callout (3) in 
), 
provide 1+1 redundancy backup. You can select either AC power supply or DC power supply.  
S7910E 
 shows the front panel of the S7910E.