Руководство Пользователя для Spectra Logic spectra t120
18
6 LCM/RCM Replacement
Before You Begin
Required Tools and Materials
You must have the following to complete this procedure:
• A #2 Phillips screwdriver
• A new LCM/RCM module P.N. 90949007
Note:
After removing the new LCM/RCM from its packaging, keep the
packaging to return the old LCM/RCM to Spectra Logic.
packaging to return the old LCM/RCM to Spectra Logic.
Continuing Backups
If the LCM/RCM is malfunctioning, you have no control of the library through the
Library Controller (LC) on the front panel or through the Remote Library Controller
(RLC).
Library Controller (LC) on the front panel or through the Remote Library Controller
(RLC).
The LCM/RCM also functions as the controller for the robotics, so an LCM/RCM
malfunction may affect robotics communication.
malfunction may affect robotics communication.
Backups should be stopped prior to replacing the LCM/RCM, and power to the library
should be shut down.
should be shut down.
Figure 6-1 The LCM/RCM module.