Release Note для Spectra Logic spectra t120

Скачать
Страница из 222
Spectra T950 Library Firmware — BlueScale10.5.0-20081121F
212
Release Notes 
90940002
Resolved Issues 
ƒ A Configuration Error screen stating that “You must provide a problem 
description for a new support ticket.” no longer displays when you 
select Send Log Set on the AutoSupport screen. 
ƒ Submitting an AutoSupport ticket in the Hardware Health Monitoring 
screen now correctly takes you to the default AutoSupport page.
ƒ The library no longer loses the SNMP connection when the LCM is 
reset. 
Known Issues
Problem
Workaround
General
Saving Auto Support ticket does not update 
progress bar in progress window. 
Be patient. The progress bar does not indicate 
changes until it is finished.
Front panel or RLC moves that are initiated 
immediately after creating a partition are not 
updated in the QIP because the library has not 
completed updating QIP inventory at the time 
the move is initiated. 
Allow sufficient time for the library to update the 
QIP inventory after creating a partition.
With Auto-Configuration Save and MLM 
enabled, the wording in the email sent when 
you edit a partition is identical to the wording in 
the one sent by the Auto-Configuration Save 
feature, even though the attached configuration 
files are different. 
ƒ The configuration file sent by the Auto-Save 
Configuration feature includes the MLM 
database. 
ƒ The email sent when you save the library 
configuration after editing a partition does 
not include the MLM database. 
Examine the zip file attached to determine which 
type of configuration file it contains.
ƒ Auto-save files are named <date-time>cfg.zip, 
where <date-time> is the time stamp for when the 
file was created.
ƒ Open the zip file sent when you update a 
partition and confirm that it contains a number 
of configuration files of the format cnnnnnn.cfg, 
where n is a number between 0 and 9, are 
present.
When you disable and then re-enable power 
consumption monitoring, the library does not 
begin capturing data until you power cycle the 
library. 
Power cycle the library to begin capturing the 
power consumption monitoring data again.
Tape Drive Firmware
An LTO-2 drive will not load a tape using 
DCM 3.18 firmware.
Upgrade the DCM firmware to the current version.
Note: Always update your library to the most 
current code available.