User Guide Updates — Importing, Exporting, and Moving Media
66
Release Notes 
90940002
To set the switch, use a small flat-head screwdriver to move the switch to 
either the unlocked or locked position, as desired. 
Importing Cleaning Cartridges into a Cleaning Partition
The cleaning partition is a special-purpose partition that is only used with 
the Automatic Drive Cleaning option. Cleaning cartridges stored in the 
cleaning partition are not accessible to the application software running on 
the host. See 
 for information 
about creating and using a cleaning partition.
When importing cleaning cartridges into a cleaning partition, keep the 
following in mind:
ƒ Make sure the cleaning cartridges are labeled and that the bar code 
labels have a CLN prefix. If you try to import cartridges with bar code 
labels that do not include the CLN prefix into a cleaning partition, the 
library rejects the magazine by reopening the TAP door without 
moving the magazine to the cleaning partition. If you attempt to import 
unlabeled cartridges, the library will warn you that the cartridge may 
be of the wrong type.
ƒ Make sure that each TeraPack magazine has a bar code label with a CL 
prefix. If you try to import a magazine without the CL bar code labels 
into a cleaning partition, the library rejects the magazine by reopening 
the TAP door without moving the magazine to the cleaning partition. 
ƒ Make sure that you import only cleaning cartridges that are compatible 
with the tape drives in the data partition associated with the cleaning 
partition. If you try to import the wrong cleaning cartridge type into a 
cleaning partition, the library rejects the magazine by reopening the 
TAP door without moving the magazine to the cleaning partition.
ƒ Make sure the TeraPack magazine does not contain any data cartridges. 
The library rejects any magazine containing data cartridges by 
reopening the TAP door without moving the magazine into the 
partition. 
Icon
Meaning
Use
Unlocked
Position the switch next to the Unlocked icon. Data can be 
written to the pack. 
Locked
Position the switch next to the Locked icon. Data cannot be 
written to the pack (that is, the pack is write-protected).