Справочник Пользователя для ASUS PIKE 2108

Скачать
Страница из 84
2-40
Chapter 2: RAID configuration
2.  Scenario #2: If some of the drives in a configuration are removed 
and re-inserted, the controller considers the drives to have foreign 
configurations. 
 
Import or clear the foreign configuration. If you select Import, automatic 
rebuilds will occur in redundant virtual drives.
Start a consistency check immediately after the rebuild is complete to ensure 
data integrity for the virtual drives.
3.  Scenario #3: If all the drives in a virtual drive are removed, but at 
different times, and re-inserted, the controller considers the drives to 
have foreign configurations.
 
Import or clear the foreign configuration. If you select Import, all drives 
that were pulled before the virtual drive became offline will be imported 
and then automatically rebuilt. Automatic rebuilds will occur in redundant 
virtual drives.
4.  Scenario #4: If the drives in a non-redundant virtual drive are removed, 
the controller considers the drives to have foreign configurations. 
 
Import or clear the foreign configuration. No rebuilds will occur after 
the import operation because there is no redundant data to rebuild the 
drives with.