Cause
Corrective Action
The Printhead nozzles are clogged.
4.
Execute Adj. Quality again.
Highly transparent film is loaded that cannot be used
for automatic feed amount adjustment.
Press the OK button to clear the error, and then adjust the feed amount manually.
Check printed document.
Check printed document.
Cause
Corrective Action
The Printhead nozzles are becoming clogged. If printing is faint, clean the Printhead.
Spectrophotometer Unit not connected.
Spectrophotometer Unit not connected.
Cause
Corrective Action
The Spectrophotometer Unit is not installed correctly. Turn off the power and reinstall the Spectrophotometer Unit.
Spectrophotometer Sensor not mounted.
Spectrophotometer Sensor not mounted.
Cause
Corrective Action
The Spectrophotometer Sensor to be loaded
into the Spectrophotometer Carriage is not in-
stalled correctly.
Turn off the power, and reinstall by pushing the two connectors all the way into the
Spectrophotometer Sensor.
Spectrophotometer Unit Calibration white tile error.
Spectrophotometer Unit Calibration white tile error.
Cause
Corrective Action
The White Calibration Tile is not
installed.
Install the White Calibration Tile.
The White Calibration Tile is
dirty.
Remove, clean, and reinstall the White Calibration Tile.
The performance of part of the
Spectrophotometer Sensor may
be impaired.
If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the
Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
Spectrophotometer Unit eject guide not mounted.
Spectrophotometer Unit eject guide not mounted.
Cause
Corrective Action
The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.
Make sure that the Spectrophotometer Eject Guide is loaded in the cor-
rect position, push it in all the way, and press the OK button.
There is a foreign object on the Spectrophotometer Eject
Guide.
Remove the foreign object and press the OK button.
The performance of part of the Spectrophotometer Unit may
be impaired.
Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your Canon dealer for
assistance.
Spectrophotometer Unit Backing plate error.
Spectrophotometer Unit Backing plate error.
Cause
Corrective Action
The White/Black Backing Plate is not in-
stalled correctly.
Remove and correctly attach the White/Black Backing Plate, and then press the OK button.
The White/Black Backing Plate is soiled.
Clean the White/Black Backing Plate and then press the OK button.
Check printed document.
                                                                                                                                                                                          
iPF6400S
                                                                                                                                                                                                                             
 
 
Error Message
Messages regarding printing or adjustment
 
990