5.  Attach power supply connector from the range hood 
to the connector on the blower motor assembly.
6.  Reinstall the heat lamp panel using the screws removed in 
the “Preparing the Internal Blower System,” (2) in the sides 
and either (3) in the back for the 36" (91.4 cm) model or (4) 
in the back for the 48" (121.9 cm) model.
7.  Reconnect the electrical connector to the heat lamp.
8.  Go to the “Make Electric Power Supply Connection 
to Range Hood” section.
Install Range Hood In-Line (External Type) 
Blower Motor
NOTE: Your range hood requires you to purchase an in-line 
(external type) blower motor system. See “Blower Motor 
System” in the “Accessories” section.
Prepare for Mounting the In-Line Blower System
The in-line blower system must be fastened to a secure 
structure of the roof, ceiling, wall, floor, or new or existing 
frame construction. The 4 holes on either the inlet (bottom) 
side or the outlet (top) side of the blower must be used to 
mount the in-line blower system to the structure.
NOTE: The mounting hole locations must span the studs. 
Additional stud framing may be required. Plywood may 
be used to span open areas between ceiling joists or roof 
rafters to aid installation. This structure must be strong 
enough to support the weight of the in-line blower system 
(50 lb [22.6 kg] min).
Prepare the In-line Blower System
1.  Using 2 or more people, move the in-line blower 
motor system to the mounting location.
2.  Remove the 10 screws from the front cover of the  
in-line blower motor housing and set them aside.
3.  Remove the front cover of the in-line blower motor 
housing and set it aside.
NOTE: To make the blower motor housing easier to 
mount, the blower motor assembly can be removed. 
If you do not want to remove the blower motor 
assembly, proceed to “Install In-line Blower System” 
in this section.
4.  Disconnect the motor electrical plug from the blower 
motor assembly.
5.  Remove the screws that secure the blower motor 
assembly to the in-line blower housing and set them aside.
6.  Pull the spring clip to release the blower motor assembly. 
Remove the blower motor assembly from the housing and 
place it on a covered surface.
B
A
A.  Blower motor assembly connector
B.  Power supply connector from range hood
A
B
A
A.  Screws - panel mounting (5) for 36” (91.4 cm) models, 
(6) for 48” (121.9 cm) models
B.  Panel - Heat lamp
WARNING
Excessive Weight Hazard
Use two or more people to move and install in-line 
blower motor system.
Failure to do so can result in back or other injury.
A
B C
D
C.  Spring clip
D.  Motor electrical plug
A.  Front cover
B.  Blower mounting screws