Использование И Уход для KitchenAid KXW9748YSS

Скачать
Страница из 36
11
Install In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes 
from either the outlet side or the inlet side of the blower.
Outlet Side:
Inlet Side:
1.  Position the in-line blower motor housing in its mounting 
location, and mark the 4 mounting hole locations.
2.  Drill 4 mounting pilot holes using a 
3
/
16
" (4.8 mm) drill bit.
3.  Attach the in-line blower motor housing to the mounting 
location with four 6 x 80 mm mounting screws and washers.
4.  If it is removed, reinstall the blower motor assembly and 
secure it with the screws previously removed.
5.  If it is removed, reattach the motor electrical plug to the 
connector on the blower motor assembly.
Complete Preparation
1.  Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall, 
do not damage electrical wiring or other hidden utilities
2.  Determine the location where the 
1
/
2
" (1.3 cm) wiring conduit 
will be routed through the ceiling or wall between the in-line 
blower and the range hood.
3.  Drill a 1
1
/
4
" (3.2 cm) hole at this location.
4.  Locate the electrical terminal boxes in the in-line blower 
housing and range hood. Remove the terminal box covers 
and set the covers and screws aside.
5.  Remove the electrical knockout from the in-line blower 
housing and range hood to prepare for the installation of 
the UL listed or CSA approved 
1
/
2
" (1.3 cm) wiring conduit 
and conduit connector.
6.  With the range hood mounted (see the “Install Range 
Hood” section), run the 
1
/
2
" (1.3 cm) wiring conduit 
between the in-line blower motor housing and the range 
hood. Pull enough 
1
/
2
" (1.3 cm) wiring conduit to allow for 
easy connection to the terminal boxes in the in-line blower 
housing and range hood.
7.  Run the six 18 AWG wires through the 
1
/
2
" (1.3 cm) wiring 
conduit and conduit connectors and into the terminal 
boxes on the in-line blower housing and range hood. 
Leave enough wire length in each terminal box to make 
the wiring connections.
8.  Install the conduit connectors and conduit to the in-line 
blower housing and range hood electrical terminal boxes.
9.  Connect the vent system to the range hood and in-line 
blower system, and seal all joints with clamps.
Make Electrical Connections for In-Line 
Blower Motor System
Electrical Connection Inside In-line Blower System:
1.  Disconnect power.
A
A
A
A
A.  Mounting holes
A
A
A.  Mounting holes
A
B
A.  Electrical terminal box
B.  Electrical knockout
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.