Инструкции По Установке для Honeywell Bypass Drum Humidifier (HE120A)

Скачать
Страница из 16
HE120 BY-PASS DRUM HUMIDIFIER
5
69-1110EF—02
7. Refer to the drawing to disassemble the drum. See Fig. 3.
Fig. 3. Drum Assembly
8. Clean all humidifier parts in a 50% solution of vinegar (or a humidifier cleaner) 
and water. Soak overnight to remove stubborn deposits.
NOTE: Replace humidifier pad yearly with the new Honeywell Drum Humidifier Pad 
(Part no. HC12A1015). The actual frequency depends on the quality of the 
water used.
9. After the humidifier components are clean, reassemble the humidifier by 
reversing the order of steps 1 through 7. 
NOTE: Be sure that the drum shaft is completely seated-listen for the click.
10. Verify the humidifier operation by following the steps in the Checking Your 
Humidifier Operation section.
Start of Humidification Season
Replace the humidifier pad with a new Honeywell Drum Humidifier Pad (Part no. 
HC12A1015) at the beginning of the heating season. Follow the cleaning instructions 
to replace the pad and check for proper operation. 
End of Humidification Season
Clean the humidifier and shut it off at the end of the heating season. Follow the 
cleaning instructions, steps 1 through 9, to shut down the device for the season. 
OPEN 
DRUM END
CLOSED DRUM END
METAL TABS
TINNERMAN
DRUM SHAFT
PAD
SQUEEZE 
SLIGHTLY 
TO INSTALL
M13609