Инструкции По Установке для Honeywell Bypass Drum Humidifier (HE120A)

Скачать
Страница из 16
HE120 BY-PASS DRUM HUMIDIFIER
69-1110EF—02
IMPORTANT
Be sure the humidifier power is off and the humidifier water pan is empty.
Vacation
When leaving on vacation, turn off the humidifier water supply and your humidity 
control. Turn on the humidifier water supply and reset your humidity control when you 
return.
CHECKING YOUR HUMIDIFIER OPERATION
After winter startup or maintenance, use the following steps to check the humidifier 
operation:
1. Turn on the humidifier power and water supply.
2. Open By-Pass Damper (if installed).
3. Check the water level in the humidifier water pan; water level setting should be 
1-3/8 in. 
NOTE: Turn the valve adjustment screw, located on the water valve inside the
humidifier, clockwise to lower the water level and counter clockwise to raise it.
4. Turn the Humidity Control to the highest setting.
5. Check that the humidifier pad is rotating.
6. Reset the thermostat and Humidity Control to a comfortable setting.
TROUBLESHOOTING YOUR HUMIDIFIER
Problem
What To Look For
What To Do
Low humidity Furnace blower not 
operating.
• Reset circuit breaker or check for blown fuse.
• Check that the furnace power is on.
• Check all external wiring connections.
• Check the humidity control setting.
• Call a professional heating contractor.
Rapid air changes. 
Drafts (cold air is dry 
and is an added load 
to the humidifier).
• Keep doors and windows closed.
• Close fireplace damper when not in use.
• Keep exhaust fan running time to a 
minimum.
• Seal around doors and windows. 
High humidity Condensation on 
walls.
• Turn off the humidity control and water until 
condensation is completely evaporated.
Heavy condensation 
on windows.
• Turn humidity control down low enough to 
eliminate condensation caused by moisture 
from bathing, mopping, cooking, etc. If 
moisture persists, more ventilation is 
needed.