Руководство По Установке для Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP)

Скачать
Страница из 10
7
Installing ONS 15454 SDH TCC-I Cards
78-14610-01
Removal Procedures
Card Turn Up
Follow the steps in this section to verify card turn up. If one or more of the Cisco Transport Controller 
(CTC) software screen conditions according to 
 are not met, re-install the card. Replace the unit if the faulty state persists.
Verify Successful Turn Up of the TCC-I Card
Step 1
Verify that power is applied to the shelf assembly.
Step 2
Verify that the TCC-I card has been installed in the correct slot (Slot 7 or slot 11).
Note
The TCC-I card takes several minutes to reboot and display the amber standby LED after rebooting.
Note
When a second TCC-I card is inserted into the shelf, it will synchronize its software, its backup 
software, and its database with the active TCC-I. 
If its software version does not match the version on the active TCC-I, the newly inserted TCC-I will 
copy from the active TCC-I. This copying will take about 15 to 20 minutes. 
If its backup software version does not match the version on the active TCC-I, the newly inserted 
TCC-I will copy the backup software from the active TCC-I. This copying, again, will take about 15 
to 20 minutes. 
Copying the database from the active TCC-I will take about 3 minutes. 
So, depending on the software existing in the new TCC-I, booting it up will take between 3 and about 
40 minutes. 
Step 3
Verify that the card appears in the correct slot on the CTC software screen.
Step 4
Verify that the card is white on the CTC software screen.
Step 5
Verify that the card is shown in Inventory on the CTC software screen.
Removal Procedures
Use this section if you are installing or removing the TCC-I card for the first time. After you become 
familiar with ONS 15454 SDH card installation and boot up, use this section as a reference. 
Caution
Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 
SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf 
assembly and ensure the shelf assembly is properly grounded.
Caution
Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution 
when servicing.