Руководство По Обслуживанию для Cisco Cisco Unified MeetingPlace Audio Server
4-18
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 4 Configuring the 8106 Server
Powering up the server
Powering up the server
This section describes how to power up MeetingPlace.
Note
The system can take 5-10 minutes to complete initialization. Please take note of the time you power up
the system and wait 10 minutes before becoming concerned if it has not come up.
the system and wait 10 minutes before becoming concerned if it has not come up.
Step 1
Move the 8106 server power switch to the on (“|”) position. See
Figure 4-19 8106 Server’s Power Switch Location
Step 2
Allow up to 10 minutes for the server to initialize. To confirm the server has come up properly, you must
connect your laptop to the 8106 server.
connect your laptop to the 8106 server.
If your laptop has not been connected and set up, complete the
and
.
If your laptop is already connected and set up, you can verify the server has come up when the laptop
displays the line “MeetingPlace is UP”.
displays the line “MeetingPlace is UP”.
Note
If the line “MeetingPlace is UP” does not appear on the laptop screen, then do the following:
•
Make sure all the cards are securely seated. Refer to
•
Turn the power switch to the off (“O”) position.
•
Check all connections to make sure they are secure.
•
After verifying that all components are secure, repeat the power up procedure. If MeetingPlace does
not properly initialize on the second try, contact the Cisco TAC.
not properly initialize on the second try, contact the Cisco TAC.
Step 3
At the prompt, enter your user name and password. Correct information causes
to appear.
This allows you to enter commands on the Command Line Interface (CLI). For information about CLI
commands, refer to
commands, refer to