Chapter 2    Installing the Series 9900 Chassis in a Rack 
 
 
 
34 
591772 Rev G 
1  Make sure that the site requirements are met as outlined in Before You Begin 
(on page 24). 
2  Insert the cable tie bases downwards into the holes in the cable tray assembly.  
Then slide the cable ties through the two loops in each cable tie base. 
 
3  Set the module chassis on top of the cable channels of the cable tray assembly as 
shown. 
 
4  Insert and tighten 4 screws that pass through the sides of the cable tray assembly 
into threaded holes in the sides of the module chassis.  Tighten the screws to 9 in-
lb (1.0 Nm). 
Result:  The module chassis is installed on the cable tray assembly.