Техническая Спецификация для Cisco Cisco UCS C24 M3 Rack Server

Скачать
Страница из 60
Cisco UCS C200 M2 High-Performance LFF Drive Rack-Mount Server
58
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C200 M2 server are listed in 
Table 29  UCS 200 M2 Environmental Specifications
Parameter
Minimum
Temperature operating
10°C to 35°C (50°F to 95°F)
Temperature nonoperating
-40°C to 65°C (-40°F to 149°F)
Altitude operating
0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases 
by 1° per 300 m
Humidity nonoperating
5 to 93%, noncondensing 
Vibration nonoperating
2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the 
three axes
Shock nonoperating
Trapezoidal, 25 G, two drops on each of six faces
Velocity = 175 inches per second on bottom face drop
Velocity = 90 inches per second on the other five faces
Electrostatic discharge
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV 
contact discharge without physical damage
Acoustic
Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23°C measured 
using the Dome Method
GOST MsanPiN 001-96