Техническая Спецификация для Cisco Cisco UCS C460 M4 Rack Server

Скачать
Страница из 60
Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server
16
CONFIGURING the SERVER
STEP 4
SELECT RAID CONFIGURATION
The base server motherboard comes with an integrated SATA RAID 0/1 controller, which supports 
up to four SATA drives only (SAS drives are not supported). Therefore, a controller is not 
required when ordering SATA drives and a RAID 0 or 1 configuration is desired.
You can use the built-in SATA RAID 0/1 controller or you can also choose to implement other RAID 
configurations by using optional plug-in PCIe cards or an optional mezzanine board on the server 
motherboard.
Cisco can provide factory-configured RAID 0, 1, 1E, 5, 6, and 10 systems depending on the RAID 
card chosen and the number of drives ordered. Factory-configured RAID options are listed with 
each RAID card description. Note that RAID levels 50 and 60 are supported on the 9280-4i4e and 
9260-8i, but are not factory configurable.
Select RAID Options
Select one RAID controller, one RAID configuration option, and, if desired, a battery backup 
option listed in 
Table 5   Available RAID Options 
Product ID (PID)
PID Description
RAID Controllers
UCSC-RAID-C-4I4E
LSI MegaRAID SAS 9280-4i4e, four internal and four external ports
Takes up one of two available PCIe slots
Supports up to four internal SAS or SATA drives (no mixing)
Supports external JBOD expansion
Battery backup option available (see the RAID Battery Backup PID section 
later in this table)
Factory-configured RAID options: RAID 0, 1, 5, 6, 10, 50, and 60 supported 
(see the RAID PIDs section in this table for factory configurable options)
RC460-PL001
LSI MegaRAID SAS 9260-8i (RAID 0, 1, 5, 6, 10)
Takes up one of two available PCIe slots
Supports up to eight SAS and/or SATA drives
Includes 512 MB of write cache
Battery backup option available (see the RAID Battery Backup PID section 
later in this table)
Factory-configured RAID options: RAID 0, 1, 5, 6, 10, 50, and 60 supported 
(see the RAID PIDs section in this table for factory configurable options)