Примечания к выпуску для Cisco Cisco Email Security Appliance C390

Скачать
Страница из 18
 
12
Release Notes for Cisco IronPort AsyncOS 7.6.1 for Email
  Known Issues
Known Issues
 lists the known issues in this release of AsyncOS for Email.
78019
Fixed: AsyncOS Upgrades and Service Updates Use Same Update Server
In AsyncOS 7.5, AsyncOS upgrades used the same update server as all of the service 
updates, whether it was an IronPort update server or a local update server. This 
prevented users from using a local server for AsyncOS upgrades and an IronPort 
update server for all other service updates unless they configure the appliance to use 
a manifest on a local appliance for an AsyncOS upgrade and then re-configure the 
appliance to use an IronPort update server for the other services after the upgrade is 
complete.
This issue has been resolved. AsyncOS 7.6 allows you to specify a different update 
server for AsyncOS upgrades than the one used for other service updates, such as 
feature key updates, outbreak filters, and time zone rules. 
75046
Fixed: Using a Virtual Gateway Hostname for a Received Header May Prevent 
DKIM Signing
Previously, AsyncOS for Email may not have signed outgoing messages using DKIM 
if the appliance uses a Virtual Gateway hostname in the received header. This issue 
has been resolved.
55066, 37034
Fixed: GUI Sometimes Displays Fewer Query Results Per Page Than Expected.
Previously, when you performed a query, the GUI sometimes displayed fewer results 
per page than expected. For example, if you selected to view 50 items of your query 
results per page, the GUI may have displayed only 20 per page, even though the page 
may have said "Displaying 1-50 of 120 items." This issue has been resolved
Table 2
Resolved Issues in AsyncOS 7.6.0 for Email (continued)
Defect ID
Description
Table 3
Known Issues for AsyncOS 7.6.0 for Email 
Defect ID
Description
82515
Application Fault May Occur When RSA Enterprise Manager DLP is Enabled 
at Group or Cluster Level
Under rare conditions, configuring a clustered ESA to use RSA EM DLP at cluster or 
group level may lead to an application fault.
81348
Admin Password Immediately Expired When Reset Password Option is Enabled
If you do not change the admin password after performing a netinstall, AsyncOS 7.6 
immediately expires the password if you enable the Password Reset option for users 
on the appliance. This only occurs if a netinstall was performed.
79841
SNMP Trap Cannot Use a URL That Has a Tilde (~) After a Slash (/)
SNMP will not generate an SNMP trap if you use a URL with a tilde (~) after a slash 
for the destination. Workaround: Make sure that the URL ends with a slash (/), 
otherwise the URL will be interpreted as a file instead of a directory.