Техническая Инструкция для Cisco Cisco Nexus 5010 Switch

Скачать
Страница из 16
Spanning Tree and FCoE VLANs
FCoE VLANs are a special case and should not exist in the spanning tree.
bdsol-n5548-05# show spanning-tree vlan 970
Spanning tree instance(s) for vlan does not exist.
A special case exists for Multiple Spanning Tree (MST) and FCoE VLANs. An instance of MST
needs to be created in order to carry FCoE VLANs, and not other VLANs. See 
VPC and FCoE VLANs
In the previous example, FCoE VLANs are added on VPCs and VPCs are on two different
devices. The configuration for trunking is slightly different for each VPC.
The FCoE VLANs will not show up as allowed VLANs in the VPC consistency check. 
bdsol-n5548-05# show vpc consistency-parameters vpc 105
   Legend:
       Type 1 : vPC will be suspended in case of mismatch
Name                        Type  Local Value            Peer Value             
-------------               ----  ---------------------- -----------------------
Shut Lan                    1     No                     No                    
STP Port Type               1     Default                Default               
STP Port Guard              1     None                   None                  
STP MST Simulate PVST       1     Default                Default               
lag-id                      1     [(1, 2-a0-98-40-ba-fa, [(1, 2-a0-98-40-ba-fa,
                                  1, 0, 0), (7f9b,       1, 0, 0), (7f9b,     
                                 0-23-4-ee-be-35, 8069, 0-23-4-ee-be-35, 8069,
                                  0, 0)]                 0, 0)]               
mode                        1     active                 active                
Speed                       1     10 Gb/s                10 Gb/s               
Duplex                      1     full                   full                  
Port Mode                   1     trunk                  trunk                 
Native Vlan                 1     1                      1                     
MTU                         1     1500                   1500                  
Admin port mode             1                                                  
Allowed VLANs               -     3380                   3380  
                
Local suspended VLANs       -     -                      -                     
This is expected.
In order to verify that the FCoE VLANs are trunked, verify per-interface trunking. 
bdsol-n5548-05# show interface port-channel 105 trunk
--------------------------------------------------------------------------------
Port          Native  Status        Port
             Vlan                  Channel
--------------------------------------------------------------------------------
Po105         1       trunking      --
--------------------------------------------------------------------------------
Port          Vlans Allowed on Trunk
--------------------------------------------------------------------------------
Po105         970,3380