Примечания к выпуску для Cisco Cisco Aironet 350 Wireless LAN Client Adapter

Скачать
Страница из 8
 
4
Release Notes for Cisco Aironet Mini PCI Client Adapter Firmware, Version 5.00.03
OL-2530-01
New and Changed Information
Step 10
Find the location of the new firmware in the Open Window’s Look in box. The default location is 
InstallPath\Firmware, where InstallPath is the directory that ACU was installed in.
Step 11
Click the firmware image file (*.img) so that it appears in the File name box at the bottom of the Open 
window.
Step 12
Click the Open button. A progress bar displays while the selected image is loaded into the mini PCI card’s 
Flash memory.
Step 13
Click OK when the “Firmware Upgrade Complete!” message appears. The OK button cannot be selected 
until the process is complete or an error occurs. 
New and Changed Information
This section describes new and changed information for release 5.00.03 of the Cisco Aironet mini PCI 
card firmware.
Ability to Periodically Scan for a Better Access Point Added to ACU
Firmware release 5.00.03 enables the client to look for a better access point if its signal strength becomes 
low and to switch associations if it finds one. This feature is selectable in ACU through the Periodically 
Scan For A Better Access Point parameter on the RF Network screen.
Note
This parameter is available only if your client adapter is using ACU version 5.02.005 or greater.
Ability to Select Clear Channel Assessment (CCA)
Firmware release 5.00.03 provides the ability to determine whether the channel on which your client 
adapter will operate is clear prior to the transmission of data. This feature is selectable in ACU through 
the Clear Channel Assessment parameter on the RF Network screen. The following methods are 
available from the parameter’s drop-down list in ACU:
Firmware Default (XXX) - The CCA mechanism reports that the channel is busy based on the 
default value of the client adapter’s firmware. The firmware’s CCA default value is shown in 
parentheses. For example, the CCA default value for PCM/LMC/PCI card firmware is Car/Cor, and 
the default value for mini PCI card firmware is ED.
Carrier/Correlation (Car/Cor) - The CCA mechanism reports that the channel is busy upon 
detection of a direct-sequence spread spectrum (DSSS) signal. This signal may be above or below 
the ED threshold.
Energy Detect (ED) - The CCA mechanism reports that the channel is busy upon detection of any 
energy above the ED threshold.
ED or Car/Cor - The CCA mechanism reports that the channel is busy upon detection of a DSSS 
signal or any energy above the ED threshold.
Note
This parameter is available only if your client adapter is using ACU version 5.02.005 or greater.