Примечания к выпуску для Cisco Cisco Broadband Access Center for Cable 4.1

Скачать
Страница из 22
 
15
Release Notes for Cisco Broadband Access Center 4.1.0.1
OL-24085-01
    Caveats
Known Problems
 lists major software issues open in the Cisco BAC 4.1.0.1.
CSCtj90972
After upgrading to BAC 4.1, the device configuration was failing with:
java.lang.IllegalArgumentException: Error occurred during parsing of MIB 
files. Cannot find MIB file [DOCS-CABLE-DEVICE-MIB-OBSOLETE].
CSCtk52701
The RDU "Device Details" page was not showing the lease information for DOCSIS 3.0 
Cable Modem.
Table 3
Resolved Problems
Bug ID
Summary
Table 4
Known Problems
Bug ID
Description
Workaround/Resolution
CSCth16781
runCfgUtil.sh fails to generate PacketCable 
2.0 dial plan TLV.
The length of the TLV values should 
not be more than 1024 characters.
CSCtg71861
Groovy scripts do not have variable bindings 
for devices.
If device object bindings are used 
inside Groovy scripts, the scripts 
cannot be encoded or decoded using 
runCfgUtil. But it can be used in RDU 
to generate the configuration files.
CSCti93245
Upgrading from Cisco BAC 4.0.1 to Cisco 
BAC 4.1.0.1 displays the following message 
without any steps as it suggests:
After migration, you should run the following 
steps to completely remove the previous 
version of BPR from your system.
Follow the instructions provided in the 
Cisco BAC 4.1.0.1 Installation guide.
CSCtj25387
EMIC configuration throws illegal argument 
exception in DPE logs.
Use encrypted secret while 
configuring EMIC shared secret in 
DPE CLI using option 7.
Use plain text while configuring 
EMIC shared secret in DPE CLI 
using option 0.
CSCtj30159
When you provide the relative path instead of 
absolute path while restoring the database, 
the following error message is displayed in 
the console:
Database recovery failed.
Provide the absolute path instead of the 
relative path.
CSCti98378
runCfgUtil decoder truncates the output TLV 
numbers. This makes it difficult to read the 
decoder output. However, this occurs only 
when the output is displayed in the user 
console.
Convert the output to a file and read the 
options and values from the file.