Supported Syslogs and Traps in Cisco Broadband Access Center 4.0 and 4.0.1
OL-22203-01
  Syslog Alerts and Messages
Network Registrar Extension Points Alerts
Whenever a BAC Network Registrar extension point syslog alert is sent, you can find additional details 
in the Network Registrar log file.
 lists the Network Registrar Extension Points alerts:
Table 5
Cisco BAC Network Registrar Extension Points Alerts
Syslog Name
Description
NR_EP-1-106: Failed to connect to 
RDU
The Network Registrar server cannot connect to the RDU. You should verify that the 
RDU process is running, and, if it is not already running, start the RDU.
If the RDU is running, use the Network Registrar computer to ping the RDU. If you 
are unable to ping the RDU, fix the routing tables or other communication 
parameters, between the two devices.
If this alert is frequently repeated, you may have an unstable connection between the 
two hosts. Use generally accepted network troubleshooting techniques to improve the 
connectivity between the two hosts.
NR_EP-1-107: Failed to connect to 
any DPEs
The Network Registrar extension cannot connect to the DPEs.
Check that there are DPEs in the provisioning group for each Network Registrar 
extension. If not, change the Network Registrar provisioning group to one that has 
DPEs available. If DPEs are in the provisioning group, ensure that the Network 
Registrar extension has registered with the RDU; if it has not, it will not recognize 
any of the DPEs.
If, after completing the check, the alert continues, check that there is network 
connectivity between the Network Registrar extension and the DPEs in the 
provisioning group.
If this alert is frequently repeated, you may have an unstable connection between the 
two hosts. Use generally accepted network troubleshooting techniques to improve the 
connectivity between the two hosts.
NR_EP-6-108: The BAC NR 
extensions have started
The Network Registrar extensions have been started.
NR_EP-6-109: The BAC NR 
extensions have stopped
The Network Registrar extensions have been stopped.
NR_EP-6-110: Registered with RDU 
[address and port]
The Network Registrar extensions have been registered with the RDU. The address 
and port
 identifies the address of the RDU that has registered the Network Registrar 
extensions.
NR_EP-1-111: Failed to find usable 
(best) DPEs
The Network Registrar extensions are unable to find a usable DPE.