Руководство По Обслуживанию для Cisco Cisco Broadband Access Center for Cable 4.0
8
Supported Syslogs and Traps in Cisco Broadband Access Center 4.0 and 4.0.1
OL-22203-01
Syslog Alerts and Messages
Network Registrar Extension Points Alerts
Whenever a BAC Network Registrar extension point syslog alert is sent, you can find additional details
in the Network Registrar log file.
in the Network Registrar log file.
lists the Network Registrar Extension Points alerts:
Table 5
Cisco BAC Network Registrar Extension Points Alerts
Syslog Name
Description
NR_EP-1-106: Failed to connect to
RDU
RDU
The Network Registrar server cannot connect to the RDU. You should verify that the
RDU process is running, and, if it is not already running, start the RDU.
RDU process is running, and, if it is not already running, start the RDU.
If the RDU is running, use the Network Registrar computer to ping the RDU. If you
are unable to ping the RDU, fix the routing tables or other communication
parameters, between the two devices.
are unable to ping the RDU, fix the routing tables or other communication
parameters, between the two devices.
If this alert is frequently repeated, you may have an unstable connection between the
two hosts. Use generally accepted network troubleshooting techniques to improve the
connectivity between the two hosts.
two hosts. Use generally accepted network troubleshooting techniques to improve the
connectivity between the two hosts.
NR_EP-1-107: Failed to connect to
any DPEs
any DPEs
The Network Registrar extension cannot connect to the DPEs.
Check that there are DPEs in the provisioning group for each Network Registrar
extension. If not, change the Network Registrar provisioning group to one that has
DPEs available. If DPEs are in the provisioning group, ensure that the Network
Registrar extension has registered with the RDU; if it has not, it will not recognize
any of the DPEs.
extension. If not, change the Network Registrar provisioning group to one that has
DPEs available. If DPEs are in the provisioning group, ensure that the Network
Registrar extension has registered with the RDU; if it has not, it will not recognize
any of the DPEs.
If, after completing the check, the alert continues, check that there is network
connectivity between the Network Registrar extension and the DPEs in the
provisioning group.
connectivity between the Network Registrar extension and the DPEs in the
provisioning group.
If this alert is frequently repeated, you may have an unstable connection between the
two hosts. Use generally accepted network troubleshooting techniques to improve the
connectivity between the two hosts.
two hosts. Use generally accepted network troubleshooting techniques to improve the
connectivity between the two hosts.
NR_EP-6-108: The BAC NR
extensions have started
extensions have started
The Network Registrar extensions have been started.
NR_EP-6-109: The BAC NR
extensions have stopped
extensions have stopped
The Network Registrar extensions have been stopped.
NR_EP-6-110: Registered with RDU
[address and port]
[address and port]
The Network Registrar extensions have been registered with the RDU. The address
and port identifies the address of the RDU that has registered the Network Registrar
extensions.
and port identifies the address of the RDU that has registered the Network Registrar
extensions.
NR_EP-1-111: Failed to find usable
(best) DPEs
(best) DPEs
The Network Registrar extensions are unable to find a usable DPE.