Closing the Mini Node Housing 
OL-31947-02 
33 
 
Closing the Mini Node Housing 
To Close the Mini Node Housing 
Complete the following steps to close the GainStar Mini Node housing. 
    CAUTION: 
Avoid moisture damage and RF leakage! Follow the procedure 
exactly as shown below to ensure a proper seal. 
1  Make sure that the housing gaskets are clean and in the correct position. Wipe off 
any excess dirt and debris. 
2  Close the housing. 
3  Lightly secure the six ½-inch closure bolts with a hex driver or ratchet. 
4  Using a torque wrench, tighten the six closure bolts to 2.8 Nm. 
Important: Tighten the closure bolts in the correct sequence as specified in 
Torquing Sequence
5  Using the same pattern, tighten the housing closure bolts from 6.8 Nm to 9.0 Nm. 
Torquing Sequence 
The following diagram shows the proper torquing sequence for the housing closure 
bolts.