Connecting the RF Cables to the Chassis 
 
OL-32414-01 
23 
 
Connecting the RF Cables to the Chassis 
To Connect RF Cables for Each Module 
Complete the appropriate procedure in this section to connect RF cables for the 
module. 
Note: This procedure assumes that the chassis is mounted in a rack. 
Standard Prisma II Chassis 
Note: This procedure assumes that you are using a host module with application 
modules installed in both lower and upper half-slot positions. If only one module is 
installed, it is not necessary to connect RF cables for the unused position. 
1  Locate the RF ports on the chassis connector panel. The connector panel is on the 
front of a front-access chassis, and on the rear of a rear-access chassis. The figure 
below shows the connector panel for a rear-access chassis. 
 
2  Connect RF cables to the Port A and Port C connectors for the chassis slot in 
which the host module will be installed. These are the RF output connections for 
the module in the lower half-slot position. Hand-tighten the connectors. 
 
3  Route the RF cables from Ports A and C (for the lower half-slot module) to the 
appropriate RF destinations.