Руководство По Установке для Cisco Cisco Prisma II EDR Receiver
Appendix A
Module Parameter Descriptions
92
78-4023013-01 Rev C
Alarm Data Parameters
Parameter
Name (LCI)
ICIM
Abbrev.
Nominal
Value
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Hys-
teresis
Operating
Range
RF
Input
Power *
InRF
0.0 dB
-1000
dB
-5.0
dB
5.0
dB
7.5
dB
1.0
-4.5 dB to
+3.0 dB
Optical
Output
Power *
OutPwr
12.0 dBm -1.0
dBm
-0.5
dBm
0.5
dBm
1.0
dBm
0.1
±0.5 dB of
nominal
CW Mode
CwMode
-
-
-
-
-
-
OK or
Fault
Laser
Temperature *
LasTemp
19.5°C
-15.0°C -5.0°C
5.0°C
15.0°C
1.0
20°C to
30°C
Laser
Bias
Current *
LasBias
50.9 mA
-20.0
mA
-10.0
mA
10.0
mA
20.0
mA
0.001
50 mA to
100 mA
Laser
Enable
Status
Enable
-
-
-
-
-
-
OK or
Fault
Power
Supply
Status
PsOk
-
-
-
-
-
-
OK or
Fault
* Alarm limit values for this parameter are relative to the nominal alarm value.