Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 126
 
Appendix A 
Module Parameter Descriptions 
92 
78-4023013-01 Rev C 
Alarm Data Parameters 
 
Parameter 
Name (LCI) 
ICIM 
Abbrev. 
Nominal 
Value 
Major 
Low 
Limit 
Minor 
Low 
Limit 
Minor 
High 
Limit 
Major 
High 
Limit 
Hys- 
teresis 
Operating 
Range 
RF 
Input 
Power * 
InRF 
0.0 dB 
-1000 
dB 
-5.0 
dB 
5.0 
dB 
7.5 
dB 
1.0 
-4.5 dB to 
+3.0 dB 
Optical 
Output 
Power * 
OutPwr 
12.0 dBm  -1.0 
dBm 
-0.5 
dBm 
0.5 
dBm 
1.0 
dBm 
0.1 
±0.5 dB of 
nominal 
CW Mode 
CwMode 
OK or 
Fault 
Laser 
Temperature * 
LasTemp 
19.5°C 
-15.0°C  -5.0°C 
5.0°C 
15.0°C 
1.0 
20°C to 
30°C 
Laser 
Bias 
Current * 
LasBias 
50.9 mA 
-20.0 
mA 
-10.0 
mA 
10.0 
mA 
20.0 
mA 
0.001 
50 mA to 
100 mA 
Laser 
Enable 
Status 
Enable 
OK or 
Fault 
Power 
Supply 
Status 
PsOk 
OK or 
Fault 
* Alarm limit values for this parameter are relative to the nominal alarm value.