Руководство По Работе для Brother Innov-is NQ550PRW / Innov-is NQ550

Скачать
Страница из 132
LCD
B-12
Adjusting input sensitivity for operation keys
You can adjust the sensitivity of the operation keys to five 
levels. Display the settings screen to set desired level.
1 Operation keys
a
Turn off the machine.
b
While pressing 
 (Reinforcement stitch button) on 
the operation panel, turn on the sewing machine.
c
Press the “-” or “+” key to select “
”.
d
Adjust the input sensitivity by pressing the “-” or “+” 
key.
• The lower the setting, the less sensitive the keys will 
be; the higher the setting, the more sensitive the keys 
will be. The default setting is “3”.
e
Press any of the operation keys, other than the “-” or 
“+” key to check the sensitivity. When the key 
responds, “
” blinks.
f
Turn off the machine, then turn it on again.
■ If the machine does not respond when an 
operation key is pressed
Turn machine off, then hold down 
 (Needle position 
button) and turn on the machine to reset the settings. Turn 
off the machine, and then adjust the settings again.
1
Note
• We recommend selecting the highest setting if 
an electrostatic touch pen is being used.
Note
• Before turning off the machine, press any of the 
keys, other than “-” or “+” key. Otherwise the 