English  11
Ins
talling the hob
Installing the hob
WARNING
Be sure the new appliance is installed and grounded only by qualified personnel. 
Please observe this instruction. The warranty will not cover any damage that may occur as a 
result of improper installation. 
Technical data is provided at the end of this manual.
Safety instructions for the installer
• 
A device must be provided in the 
electrical installation that allows the 
appliance to be disconnected from the 
mains at all poles with a contact opening 
width of at least 3 mm. Suitable isolation 
devices include line protecting cut - 
outs, fuses (screw type fuses are to be 
removed from the holder), earth leakage 
trips and contactors.
• 
With respect to fire protection, this 
appliance corresponds to EN 60335 - 
2 - 6. This type of appliance may be 
installed with a high cupboard or wall on 
one side.
• 
The installation must guarantee shock 
protection.
• 
The kitchen unit in which the appliance 
is fitted must satisfy the stability 
requirements of DIN 68930.
• 
For protection against moisture, all cut 
surfaces are to be sealed with a suitable 
sealant.
• 
On tiled work surfaces, the joints in 
the area where the hob sits must be 
completely filled with grout.
• 
On natural, artificial stone, or ceramic 
tops, the snap action springs must be 
bonded in place with a suitable artificial 
resin or mixed adhesive.
• 
Ensure that the seal is correctly seated 
against the work surface without any 
gaps. Additional silicon sealant must not 
be applied; this would make removal 
more difficult when servicing.
• 
The hob must be pressed out from below 
when removed.
• 
A board can be installed underneath the 
hob.
• 
The ventilation gap between the 
worktop and front of the unit 
underneath it must not be covered.
NZ84J9770EK_EO_DG68-00631A-01_EN.indd   11
2015-02-05     6:11:45