Справочник Пользователя для ATIKA bioquick 2500

Скачать
Страница из 127
 
 
11
− 
Do not leave the machine standing in the rain or use 
when raining. 
− 
Provide for good illumination
ƒ 
To prevent danger of injury to fingers during assembly or 
cleaning operations hold the cutting mechanism (see pic. 
page 13) and wear protecting gloves.  
ƒ 
Switch the machine off and remove the mains plug from the 
socket
 when 
− 
Performing maintenance and cleaning work. 
− 
Eliminating  faults. 
− 
Checking connecting lines, whether these 
are knotted or damaged. 
− 
Transporting. 
− 
Carrying out repair work. 
− 
Changing the blades. 
− 
Leaving unattended (even during short interruptions). 
ƒ 
If the machine’s filling funnel or ejection slot is blocked switch 
off the motor and disconnect the mains plug before removing 
material from the filling funnel or ejection slot. 
ƒ 
Check the machine for possible damage
− 
Before further use of the machine the safety devices must 
be checked carefully for their proper and intended func-
tion. 
− 
Check whether movable parts function perfectly and do 
not stick or whether parts are damaged. All parts must be 
correctly installed and fulfil all conditions to ensure perfect 
operation of the machine. 
− 
Damaged safety devices and parts must be properly re-
paired or exchanged by a recognized, specialist workshop; 
insofar as nothing else is stated in the instructions for use. 
− 
Damaged or illegible safety labels have to be replaced. 
ƒ 
Store  unused equipment in a dry, locked place out of the 
reach of children. 
 
  
E
E
l
l
e
e
c
c
t
t
r
r
i
i
c
c
a
a
l
l
 
 
s
s
a
a
f
f
e
e
t
t
y
y
 
 
 
ƒ 
Design of the connection cable according to IEC 60 245 (H 
07 RN-F) with a core cross-section of at least 
− 
1.5 mm
2
 for cable lengths up to 25 m 
− 
2.5 mm
2
 for cable lengths over 25 m 
ƒ 
Long and thin connection lines result in a potential drop. The 
motor does not reach any longer its maximal power; the func-
tion of the device is reduced. 
ƒ 
Plugs and coupler outlets on connection cables must be made 
of rubber, plasticised PVC or other thermoplastic material of 
same mechanical stability or be covered with this material. 
ƒ 
The connector of the connection cable must be splash-proof. 
ƒ 
When running the connection line observe that it does not 
interfere, is not squeezed, bended and the plug connection 
does not get wet. 
ƒ 
Wind off completely the cable when using a cable drum. 
ƒ 
Do not use the cable for purposes for which it is not meant. 
Protect the cable against heat, oil and sharp edges. Do 
not use the cable to pull the plug from the socket. 
ƒ 
Regularly check the extension cables and replace them if 
they are damaged. 
ƒ 
Do not use any defective connection cables
ƒ 
When working outdoors, only use extension cables especially 
approved and appropriately labelled for outdoor use. 
ƒ 
Do not set up any provisional electrical connections
ƒ 
Never bypass protective devices or deactivate them. 
ƒ 
Only hook up the machine by means of a fault-current cir-
cuit breaker
 (30 mA). 
 
  The  electrical connection or repairs to electrical parts of 
the machine must be carried out by a certified electrician or 
one of our customer service points.  Local  regulations  –     
especially regarding protective measures – must be ob-
served. 
 
Repairs to other parts of the machine must be carried out 
by the manufacturer or one of his customer service points. 
  Use only original spare. Accidents can arise for the user 
through the use of other spare parts. The manufacturer is 
not liable for any damage or injury resulting from such ac-
tion. 
 
 
C
C
o
o
m
m
m
m
i
i
s
s
s
s
i
i
o
o
n
n
i
i
n
n
g
g
 
 
 
ƒ 
Check that the machine is completely and correctly assem-
bled. 
ƒ 
To avoid toppling, place the shredder on a firm horizontal 
surface. 
ƒ 
Do not place the equipment on ground which is paved or 
surfaced with gravel. 
ƒ 
The machine should only be operated in the open. Always 
maintain a safe distance (at least 2 m) from walls or other 
fixed objects. 
ƒ 
Before each use, check 
− 
Connection cables for defects (cracks, cuts, etc.). 
 Do not use any defective cables. 
− 
There are no damage at the machine (see safety instruc-
tions). 
− 
All screws are tight. 
L
 Mains connection 
ƒ 
Compare the voltage given on the machine model plate e.g. 
230 V with the mains voltage and connect the machine to the 
relevant and properly earthed plug. 
ƒ 
Only use extension cables with sufficient core cross-section. 
 
 
Mains fuse 
  
Switzerland 
UK 
2300 W 
16 A time-lag  
 
10 A time-lag  
 
13 A time-lag  
 
2500 W 
16 A time-lag  
 
 
13 A time-lag