Make sure that the fan runs briefly, which indicates that the power supply is operational.
4
Make sure that the control-panel display wire-harness is connected. See 
5
Make sure that the firmware flash memory card and the formatter are seated and operating
correctly. Verify that the compact flash card is in slot 1. See 
.
6
Remove any HP Jetdirect or other EIO cards, and then try to turn the digital sender on again.
7
Verify that the formatter “heartbeat” LED is blinking. See 
. The
heartbeat LED indicates that the formatter is fully functional. If the heartbeat LED is not blinking,
reseat the compact flash card and the formatter assembly.
If the scanner base fan is not operating, verify that all connectors to the power supply and the
scanner base fan are correctly seated. If the fan is still not functional, replace the components one by
one until the system is functional.
NOTE
It is important to have the control panel functional as soon as possible in the
troubleshooting process so that the control-panel display can be used to help locate digital-
sender errors.
Understanding the troubleshooting process