(PSW)  Although a print job was aborted in the 
middle, PSW displays "Print completed" message. 
All 
Compliant 
with 
specifications 
Compared to previous LBP-810, the 
current version displays false "Print 
completed" more often, and takes longer 
time to stop print operation.  (One to 
three more pages are printed before the 
operation stops.)  It seems that as if the 
former and new versions make different 
operations.  Usually, when process stops 
with "Print aborted" or "Print completed" 
message, PSW automatically closes, 
hence no influence upon the user.  Print 
operation is stopped not when the abort 
command is received, but when data 
spooled before abortion has been output. 
(PSW)  For each Centronics error, 2 lines of "Print 
result = NG" is recorded in the print job log. 
All 
Scrutiny on 
the 
specifications 
is required. 
Although the double NG logging is not 
charming, subsequent operations are 
normal.