DFE Module Placement and Installation Rules
3-4 Installation
To ensure proper operation of the system, consider the following examples and rules for 
module placement in either chassis.
Example 1 (
, A) 
Shows one module installed in the chassis. If the chassis is populated with only one 
4xxxxx, it must be installed in slot 1. 
Rule: If only one 4xxxxx is installed in the chassis, it must be in slot 1. Always install a 
4xxxxx in slot 1 of the chassis.
Example 2 (
, B) 
Shows the chassis fully populated with 4xxxxx modules. All modules may be hot 
swapped, except the module in slot 1. If the module in slot 2 is designated as a redundant 
management module, the module in slot 1 may be hot swapped without shutting down 
the system. The module in slot 2 can be designated using the CLI command 
set license <license key>.
For information on how to use this command, refer to the Enterasys Matrix DFE‐Gold Series 
Configuration Guide
. To access this guide on the web, refer to 
Without a designated redundant management module in slot 2, removing the module in 
slot 1 will shut down the system.
Rule: Any module in a 4xxxxx system, including the management module in slot 1, may 
be hot swapped when there is a 4xxxxx module designated as a redundant management 
module in slot 2.