Справочник Пользователя для Atmel ATAK2270
Host Software
5-12
RFID Application Kit ATAK2270 User Manual
4871E–RFID–04/08
Figure 5-15. Extended Mode Main Read Tab
Selecting Extended Mode displays the Read tab (
). The Read tab is divided into two areas –
Configuration Setup and Read Timings.
5.3.4.3
Configuration Setup
Bitrate: Rf / (n + 2) for n = 0 to 126 (default setting Rf/32)
Coding: Manchester, Biphase 1('50), Biphase 2 ('57), Direct, PSK..., FSK,...
(refer to the T5557 datasheet), (default = Manchester)
ID-Code Length: Block0, Block1, Block 1 to 2, Block 1 to 3, ..., Block 1 to 7 (default = Block 1 to 7)
Signature: 8-bit Header, Sequence Start Terminator (default = Header 6Eh)
Use 12-bit Header: RFID application complying to the ISO/IEC 11784/85 standard. For example, for
animal IDs, the 11-bit binary header 0000 0000 001(0) is used. For this reason, a three-nibble header
window is specified (default = 002h)
animal IDs, the 11-bit binary header 0000 0000 001(0) is used. For this reason, a three-nibble header
window is specified (default = 002h)
Password: Activates password mode used for protection against overwriting and Answer On Request
(AOR) Function (default = not activated)
(AOR) Function (default = not activated)
Lock Block 0: Setting this bit locks the Configuration Block 0 of the transponder. Once the lock bit is
set, the bit rate, coding etc., are locked and cannot be changed. Use this feature with care.
set, the bit rate, coding etc., are locked and cannot be changed. Use this feature with care.
Inverse Data: Data uplink is performed inversely when activated (default = not activated)
Answer On Request (AOR): Activates anticollision mode. (When this check box is selected, an
additional button appears for AOR wake-up.) (Not activated is the default.)
additional button appears for AOR wake-up.) (Not activated is the default.)