Справочник Пользователя для Siemens siemens network router mc35

Скачать
Страница из 65
Remote-SAT User's Guide
MC35_SAT_01_v02.00
Page 32 of 65
11.01.2002
1.4.9  AT^SSTGI  Remote-SAT Get Information – Play Tone (32)
Write command
AT^SSTGI=32
This command is to be used upon receiving an unsolicited result code
^SSTN:32.
The ME has been instructed to generate an audible tone, and may pass to the
TA some information to support this.
Text and an Icon Identifier are passed to the TA for display to the user.
Response
^SSTGI: <cmdType>, <commandDetails>, <infoText>>, <tone>, <durationUnit>,
<duration>, <iconQualifier>, <iconId> <CR> <LF>
Parameters
<cmdType>
32 – Proactive command ID, see Table 1.
<commandDetails>
This byte is RFU.
<infoText>
String to accompany tone
<tone>
Tone that the ME generates
Standard supervisory tones:
01
Dial tone
02
Called subscriber busy
03
Congestion
04
Radio path acknowledge
05
Radio path not available / Call dropped
06
Error / Special information
07
Call waiting tone
08
Ringing tone
ME proprietary tones:
10
General beep
11
Positive acknowledgement tone
12
Negative acknowledgement or error tone
<durationUnit>
0
Minutes
1
Seconds
2
Tenths of Seconds
<duration>
Duration of tone, expressed in units (1-255)
<iconQualifier>
Unsigned Integer, range 0 – 255, used as a bitfield.
bit 1:
0
icon is self explanatory and replaces text
1
icon is not self-explanatory and shall be displayed with
the text. Determined value only if associated icon id is not
0 (an icon exists).
bits 2-8:
RFU
<iconId>
0-255, 0: no icon
Reference
Siemens
Note
Command is issued if the SIM application requests playing a tone with a length
more than 5 seconds.