Справочник Пользователя для Alliance Laundry Systems 1336

Скачать
Страница из 111
PowerFlex 40 and 400 Drive Control Logic
7
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Interference
EMI
Careful attention must be given to the arrangement of 
power and ground connections to the drive to avoid 
interference with nearby sensitive equipment. Be sure 
to replace all ground connections to their appropriate 
locations.
RFI
Drives can be installed with an RFI filter, which 
controls high-frequency conducted emissions into the 
main supply lines.
Where it is essential that very low emission levels 
must be achieved or if conformity with standards is 
required, the optional RFI filter may be present. 
Figure 5 displays an electrical schematic for various 
RFI configurations. Table 2 shows associated RFI 
filter part numbers.
Figure 5 
CAUTION
ELECTRIC SHOCK HAZARD! Service and 
maintenance to be performed only by an 
authorized technician. Disconnect power 
before opening any access panels.
W661
U166ME3A
L1
TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE  NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.
L2
ALLEN-BRADLEY
RFI
FILTER
L3
LINE
LOAD
PROVEN EARTH GROUND
WASHING
MACHINE
GROUNDING
TERMINAL
THREE PHASE MACHINES
INPUT
POWER
1 2
3
2
3
L1
TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE  NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.
L2
ALLEN-BRADLEY
RFI
FILTER
LINE
LOAD
PROVEN EARTH GROUND
WASHING
MACHINE
GROUNDING
TERMINAL
SINGLE PHASE MACHINES
INPUT
POWER
1 2
3
2
3
U166ME3A
RFI Filter Part Number Information
Drive P/N
Drive Catalog
Machine Voltage
Filter P/N
F8044301 and F8168603
22B-B017N104xx
200-240V 50-60Hz 3 phase
F8053901
F8044401 and F8168604
22B-D010N104xx
380-480V 50-60Hz 3 phase
F8053902
F8044701 and F8168601
22B-B012N104xx
200-240V 50-60 Hz 3 Phase
F8053901
F8044901 and F8168602
22B-D6P0N104xx
380-480V 50-60 Hz 3 Phase
F8053902
C002501 and F8168701
22B-B024N104xx
200-240V 50-60 Hz 3 Phase
F8054001
C002502 and F8168702
22B-D012N104xx
380-480V 50-60 Hz 3 Phase
F8054002
C002507 and F8168705
22B-D024N104xx
380-480V 50-60 Hz 3 Phase
C002569
C002502, F200309300 
and F8168703
22B-B033N104Axx
200-240V 50-60Hz 3 phase
F8054001
C002506, F200309400 
and F8168704
22B-D017N104Axx
380-480V 50-60Hz 3 phase
F8054002
Table 2