Gas Requirements
IMPORTANT: Any product revisions or conversions 
must be made by the Manufacturer’s Authorized 
Dealers, Distributors or local service personnel.
IMPORTANT: The tumbler must be isolated from 
the gas supply piping system by closing its 
individual manual shut-off valve during any 
pressure testing of the gas supply piping system at 
test pressure equal to or less than 0.5 psig 
(3.45 kPa, 34.5 mbar).
IMPORTANT: The tumbler and its manually 
operated appliance gas valve must be disconnected 
from the gas supply piping system during any 
pressure testing of that system at test pressures in 
excess of 0.5 psi (3.45 kPa, 34.5 mbar).
IMPORTANT: The installation must comply with 
local codes or, in the absence of local codes:
with the latest edition of the “National Fuel 
Gas Code,” ANSI Z223.1/NFPA 54 in the 
U.S.A.,
with CAN/CSA-B149.1 or Natural Gas and 
Propane Installation Code in Canada,
and Australian Gas Association/Australian 
L.P. Gas Association requirements in 
Australia.
Obtain specific gas service pipe size from the gas 
supplier. Refer to Table 5
 
for general pipe size.
The following must be furnished and installed by the 
customer for the gas service line to each tumbler. 
Refer to Figure 18
Sediment traps
Shut-off valves
Supply pressure taps
It is important that equal pressure be maintained at all 
tumbler gas connections. This can be done by 
installing a 1 inch (25.4 mm) pipe gas loop to maintain 
equal pressure at all gas connections. Refer to 
Figure 19
NATURAL GAS line pressure must be maintained at 
7 ± 1.5 inch water column pressure (1.74 ± 0.37 kPa) 
with all gas appliances running (tumblers, water 
heaters, space heaters, furnace, etc.). An in-line 
pressure regulator may be required if the line pressure 
exceeds 8 water column inches (2.0 kPa) with all gas 
appliances running.
LIQUID PETROLEUM GAS (L.P.) line pressure must 
be maintained at 11 ± 0.3 water column inches (2.74 ± 
0.07 kPa) with all gas appliances running (tumblers, 
water heaters, space heaters, furnace, etc.).
CE GASES refers to Installing CE Gas Drying 
Tumblers 
section, the above data does not apply to the 
CE.
WARNING
To reduce the risk of fire or explosion, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLER IF THE GAS SERVICE IS NOT 
THE SAME AS THAT SPECIFIED ON THE 
TUMBLER SERIAL PLATE! It will first be 
necessary to convert the gas burner 
orifice and gas valve. Appropriate 
conversion kits are available.
W060
WARNING
To reduce the risk of fire or explosion, if 
the tumbler is to be connected to 
Liquefied Petroleum (L.P.) gas, a vent to 
the outdoors must be provided in the 
room where the tumbler is installed.
W062