Справочник Пользователя для Alliance Laundry Systems sc50

Скачать
Страница из 150
33
Installation
F232062
Elevated Base Frame Installation
(2-Speed Models Only)
Note: The 3-speed and variable-speed 
models should not be installed on elevated 
base frames.
Factory-built elevated steel base frames are 
designed to meet the specifications of the 
2-speed model washer-extractor. See 
Figure 21.
Figure 21
Use the following instructions and Figures 
22 through 26 as a step-by-step guide to 
installation of the elevated base frame.
1. Verify that the floor is 3500 psi minimum 
reinforced concrete embedded in clean, 
compacted fill dirt. The floor must be at 
least 4 inches (102 mm) thick.
2. Use the elevated base frame as a template 
by positioning the frame in the desired 
location and marking the pre-drilled 
mounting holes on the floor. See 
Figure 22.
Figure 22
3. Adjust the drill depth gauge to match the 
length of the J-bolt, minus 1-1/2 inches 
(38 mm). See Figure 23.
Figure 23
H035I
H025I
H026I